SEARCH OUR PRODUCT CATALOG

PLAG1 FISH Probe

The PLAG1 FISH probe is designed to hybridize to the PLAG1 gene and is primarily used for detecting amplifications and deletions associated with the gene. This probe is FISH confirmed on normal peripheral blood metaphase spreads and interphase nuclei. The probe can be labeled in one of five colors. Each probe is sold in a 20 test kit (approximately 20 slides - 22x22 mm area) and includes hybridization buffer. Please note that due to design optimizations, prices are subject to change.

** This product is for in vitro and research use only. This product is not intended for diagnostic use.

.
Turnaround Time: 7-10 Business Days    Shipping Time: 1-2 Day Expedited Shipping

SKU Test Kits Buffer Dye Color Order Now
PLAG1-20-OR  (Standard Design) 20 (40 μL) 200 μL
PLAG1-20-RE 20 (40 μL) 200 μL
PLAG1-20-GO 20 (40 μL) 200 μL
PLAG1-20-GR 20 (40 μL) 200 μL
PLAG1-20-AQ 20 (40 μL) 200 μL
PLAG1-20-DIG 20 (40 μL) 200 μL
PLAG1-20-BIO 20 (40 μL) 200 μL

Gene Summary

Pleomorphic adenoma gene 1 encodes a zinc finger protein with 2 putative nuclear localization signals. PLAG1, which is developmentally regulated, has been shown to be consistently rearranged in pleomorphic adenomas of the salivary glands. PLAG1 is activated by the reciprocal chromosomal translocations involving 8q12 in a subset of salivary gland pleomorphic adenomas. Three transcript variants encoding two different isoforms have been found for this gene. [provided by RefSeq, Jul 2008]

Gene Details

Gene Symbol: PLAG1

Gene Name: PLAG1 Zinc Finger

Chromosome: CHR8: 57073467-57123859

Locus: 8q12.1

FISH Probe Protocols

Protocol, Procedure, or Form Name Last Modified Download

Epithelial-Myoepithelial Carcinoma Frequent Morphologic and Molecular Evidence of Preexisting Pleomorphic Adenoma, Common HRAS Mutations in PLAG1-intact and HMGA2-intact Cases, and Occasional TP53, FBXW7, and SMARCB1 Alterations in High-grade Cases

There is though to be a relationship between genetic aberrations, preexisting pleomorphic adenoma (PA), and the structural abnormality of epithelial-myoepithelial carcinomas (EMCAs). EMCAs were analyzed on a molecular level for PA by using FISH. FISH analysis was used with our break apart probes to detect PLAG1 and HMGA2 rearrangements. It was found that a relationship was present, as 80% of EMCA arise from PA, and EMCA genetics can vary with the status of PLAG1 and HMGA2.

Recurrent rearrangements of the PLAG1 and HMGA2 genes in lacrimal gland pleomorphic adenoma and carcinoma ex pleomorphic adenoma

Lacrimal gland tumors are histologically similar to salivary gland tumors. In the salivary glands, pleomorphic adenoma (PA) and carcinoma ex pleomorphic adenoma (ca_ex_PA) are both characterized by PLAG1 and HMGA2 gene rearrangements. However, it is not known if these rearrangements are present in lacrimal gland PA and ca_ex_PA. FISH analysis was done with our PLAG1, HMGA2, and NFIB break apart probes. It was found that rearrangements were frequent in the tested lacrimal glands and that testing for the rearrangement can help in distinguishing lacrimal gland PA and ca_ex_PA from de novo carcinomas.

Plasmacytoid cells in salivary pleomorphic adenoma. An alternative interpretation of their immunohistochemical characteristics highlights function and capability for epithelial-mesenchymal transition

Plasmacytoid cells (PLCs) are frequently reported components of salivary pleomorphic adenoma (SPA), and regarded as modified myoepithelial cells. In rare cases where a SPA is composed mostly of PLCs, the neoplasm is referred to as plasmacytoid myoepithelioma (pMYO). A genetic hallmark of SPA is rearrangement of PLAG1. In this study, 3 pMYOS were analyzed for PLAG1 translocations using Empire Genomics’ PLAG1 break apart probe, to determine whether this aberration is shared by both tumor types. PLAG1 was found rearranged in 1 out of 3 pMYOs.

Molecular Diagnostics in Pediatric Cytopathology

Compared to adult neoplasms, only a small portion of pediatric tumors display large epithelioid morphology, including certain salivary gland, thyroid, hepatic, and head and neck tumors. FISH testing can be used to elucidate the identity of these cancers in pediatric and adolescent patients, as many of these tumor types harbor characteristic translocations. One of the cases in this book involved FISH analysis of an 18-year-old boy’s parotid gland lesion. Empire Genomics’ PLAG1 dual-color break-apart probe was used to test for PLAG1 gene rearrangements. Results were positive, clarifying the tumor’s identity as pleomorphic adenoma or benign mixed tumor.

Metastasizing Pleomorphic Adenoma: Recurrent PLAG1/HMGA2 Rearrangements and Identification of a Novel HMGA2-TMTC2 Fusion

Pleomorphic adenoma (PA), although considered benign, can undergo malignant transformation, and metastatic cases are well documented. There is a lack of research on genetic characterization of metastasizing versus benign PA. In this study, four cases of metastasizing PAs were cytogenetically profiled using both RNA sequencing and FISH. PLAG1 and HMGA2 break-apart probes from Empire Genomics were used to confirm rearrangements of the genes. PLAG1 rearrangements were detected in all four cases. Results demonstrated that MPA harbors the same disease-defining molecular hallmarks as their benign counterparts.

Three Novel Aberrations Involving PLAG1 Leading to Lipoblastoma in Three Different Patients: High Amplification, Partial Deletion, and a Unique Complex Rearrangement

Lipoblastoma is a rare benign neoplasm that can be difficult to histologically distinguish from other lipomatous tumors. PLAG1 aberrations are recurrent in lipoblastoma. The subjects of this study were 3 pediatric lipoblastoma patients with varying types of PLAG1 aberrations (including deletions, amplifications, and rearrangements), all which resulted in different modes of PLAG1 upregulation. Our PLAG1 break apart probe was used to detect PLAG1 rearrangements in the tumors.

Fluorescence in situ Hybridization in Cytopathology

This textbook – Modern Techniques in Cytopathology – references our PLAG1 break apart probe for detecting PLAG1 rearrangements in epithelial cells. The chapter focuses specifically on FISH, expanding on the different types of mutations that can be detected with FISH, including examples of several disease-specific mutations with accompanying probe recommendations.

Giant Cell Carcinosarcoma of the Parotid Gland With a PLAG1 Translocation in Association With a Pleomorphic Adenoma With HMGA2 Translocation: A Case Report and Fluorescence In Situ Hybridization Study

This case study looked at a parotid gland carcinosarcoma in a 77 year old patient. Our PLAG1 and HMGA2 break apart probes were used to detect rearrangements of the genes in both the carcinomatous and sarcomatous components of his tumor, to determine whether they harbored different genetic lesions. Both components were positive for PLAG1 and negative for HMGA2 translocations.

Product Details

Product: PLAG1 FISH Probe

Test Kits: 20 (40 μL)

ISH Buffer: 200 μL

SKU: PLAG1-20-OR

Material Safety Data Sheet: MSDS.pdf

Turnaround Time: 7-10 Business Days

Shipping Time: 1-2 Day Expedited Shipping